Carrier Furnace AC Upgrade
Installed a new 80-90 system with a 59TP7A060V17–16 furnace, 26SPA624 condenser, vertical cased coil, new Ecobee thermostat, condensate pump, and updated 16×25 filter boot and 10×25 return drop while reusing and flushing the existing lineset. Set fan speed to 1000 CFM, verified superheat and subcool to match the condenser specs, walked through the system operation with the homeowner, and collected the check once everything was running smoothly.