Furnace & Heat Pump Install
Installed a Carrier 59TP6C furnace with a 2-ton Performance 18 heat pump and matching coil, added an Ecobee 3 stat, Aprilaire 600 humidifier, condensate pump, and new return drops with a 16×25 filter boot. Swapped the planned 40-gal short power-vent for a 40-gal tall due to damage, set gas pressures, updated venting using the existing 6″ penetration, and verified heating and cooling during the walkthrough.