Carrier AC Installation
Installed a new 2-ton Carrier condenser with a matching indoor coil, flushed and pressure-tested the lineset, and temporarily wired the system pending the electrician for the thermostat. Built a new plenum transition with a 2×12 register, leveled the pad with pea gravel per the homeowner’s request, charged the system, and confirmed cooling.