Heat Pump Installation
Installed a new 2.5-ton heat pump with matching cased A-coil, reused and flushed the existing lineset, and kept the current thermostat, drop, and boot in place with a 16x25x1 filter. Removed old metal and reworked the plenum with new canvas and transitions for the coil and humidifier, relocated piping and the controller, moved the outdoor unit beside the disconnect, and set the heat pump to run at a higher balance temperature per the customer’s preference.